- Air-conditioning System
- Mechanical Ventilation
- Emergency Lifts and Lighting
- Emergency Warning System
- Fire Hydrants
PMG South Headland & Karratha
Client: Pilbara Motor Group Year: 2017 & 2019 Mechnaical work value: $1.2M each
- Ducted rooftop package units with energy recovery ventilation (ERV) system ,split Air Conditioning systems design for tropical cyclone region
- Heat load calculation and design complying with AS1668.1 &2 and NCC 2016 section J5
- Detail design of the offices, 2 storey height showroom and workshop, mezzanine level lunch room, board room and comms room
- Equipment/material selection according to client specifications and energy efficiency standards
- Provided equipment installation spec including air conditioning, refrigeration system, pipe works, fully insulated sheet metal and flexible duct works, filters, etc. to comply with AIRAH DA09.
- Recommended manufacturers/suppliers from the HKS database
- Selection of fans according to tropical Region classifications
- Incorporated Air Curtain
- Innovative Solutions:
- Improved operation and longevity of extraction fans through Intelligent Scheduling utilising CO monitoring sensors for workshop linked to roller doors and air curtains
- Increased energy efficiency and humidity reduction in offices and showrooms utilizing ERV and CO2 sensors linked to individual ducted split AC system